Full 1
TissueFAXS Q & SL Q
CONFOCAL TISSUE CYTOMETERS
Full 1

TissueFAXS Q & SL Q Systems
Confocal Tissue Cytometer

TissueFAXS Q & SL Q Systems provide the benefits of both high-throughput of slides and laser-free fast confocal imaging. All TissueFAXS Fluo or PLUS system configurations, irrespective of whether they are upright or inverted, are also available as TissueFAXS Q configurations.

STissueFAXS Q systems are also available in scan only configurations.

 

TissueFAXS Q
KEY FEATURES

  • Whole slide confocal imaging
  • High-speed and high-resolution confocal imaging
  • LED-based technology
  • Multi-channel fluorescence & brightfield imaging
  • Inverted or upright
  • Upgrade SL Q: high-thoughput scanning - up to 120 slides 
  • Slide ID Scanner
  • Quantitative image analysis option
  • Default
  • Title
  • Date
  • Random

CONFIGURATION

TissueFAXS Q system comes in an upright, inverted, PLUS and slide loader (SL) configuration. The most advanced TissueFAXS Q system is the TissueFAXS SL Q+.

The TissueFAXS SL Q+ combines TG´s versatile Spinning Disc Confocal Kit with TissueFAXS SL autoloader capabilities and with TissueQuest/HistoQuest and/or StrataQuest image analysis software. 

TissueFAXS Q+ systems also provide all other scanning modes (i.e. brightfield and epifluorescence) of a non-confocal TissueFAXS system.

All epifluorescence TissueFAXS systems (upright and inverse) can be upgraded to TissueFAXS Q configuration at any time.

    TissueFAXS Q long

TMA Analysis with StrataQuest

Tissue microarrays (TMAs) have proven themselves as a standard molecular clinical diagnosis technique. TMAs are paraffin blocks in which up to 1000 individual tissue cores assembled in array fashion, allowing high-throughput histological analysis.

The TissueFAXS platform including the high-end image analysis solution StrataQuest provides specific workflow to scan and analyze the TMA samples containing multiple regions on one slide. TMA analysis in StrataQuest is available for images acquired in all imaging modalities (multispectral, fluorescence, brightfield).

In the first example, StrataQuest was utilized to analyze a TMA sample stained for hematoxylin (blue) and for E-cadherin present in the cell membranes of epithelial cells (brown). On the original image (a), E-cadherin is shown in brown and nuclei in blue. The aim was to detect the nuclei, the epithelial cells and the membranes of epithelial cells. The challenge with this analysis was that some cells do not contain nuclei.  

TMA Immune status Overview 15 name

Image (b) shows detected nuclei, covered by nuclei mask in light blue. Next only membranes were detected (c), which are shown in green; (d) shows the detection of the whole E-cadherin+ epithelial tissue, also marked in green.

 

Bild1 cut

In image (e) only cells with nuclei are identified, and the whole cell with the membrane is shown in blue, while the nuclei are covered by the light blue nuclei mask; (f) represents the nuclei in light blue and the total membranes in red.

 

Bild2 cut

Another example on TMA analysis is our IHC Immune Status in situ APP. Here the task was to develop a streamlined workflow for tissue classification (epithelium, stroma, lymphoid cluster).

Marker positive cells (for CD3+) were identified and spatial analysis was peformed, which would allow for the calculation of how many and which types of cells are located in defined distances from the object of interest (epithelium or lymphoid cluster). In the below example the App was applied to Tissue Microarrays (TMA) of an inflamed bladder.

 

TMA Immune status Overview 15 cut

One of the most notable features of StrataQuest is the machine learning-based tissue classification. To train the algorithm, the user marks regions assigned to different tissues and trains the classifier on the sample; later this workflow can be used on other samples. The following images represent the outcome of the classifier: (g) epithelium is detected in blue; (h) displays the lymphocyte cluster in light blue. These algorithms (or masks) can be combined to achieve a better visualization: (i) epithelium is displayed in blue, lymphocyte cluster in light blue and stroma in yellow.

 

TissueClassification cut

Beside the tissue classification itself, StrataQuest is capable of performing proximity analysis. It is possible to define specific proximity ranges; in the following case each range marked by different colors is 20µm. Nuclei detection was applied and CD3+ cells are shown in green, negative cells in yellow; (j) proximity ranges for the epithelium and (k) proximity ranges for the lymphocyte cluster.

 

TissueClassification2 cut

Apart from visual image analysis, StrataQuest outputs quantitative numbers. This way, it is possible to acquire and validate much more information. For example, StrataQuest can show how many cells are detected in each range: through the establishment of gates, 5.06% of CD3+ cells were found to be very close (in 20 µm range) to the epithelium.

 

scattergram Tumor Ranges edited cut

Further details about our various products and services can be found on our website. If you are interested in learning more about TissueGnostics solutions for TMA application or other tissue cytometry applications and our related services, please reach out to a member of the TissueGnostics team.

TF SLQ

   

TissueFAXS SL Q

The TissueFAXS SL Q is a highly flexible scanning platform, capable of scanning up to 120 slides at a time in brightfield, widefield fluorescence, and confocal fluorescence.

TissueFAXS Q delivers automated whole slide confocal imaging using a confocal spinning disk, paired with a high power LED light engine and the TissueFAXS automated scanning workflow. All TissueFAXS FL or PLUS systems, irrespective of whether they are upright or inverted, are also available in TissueFAXS Q configuration.

Upright configurations of the TissueFAXS Q can be upgraded with a 120 slide loader for high-throughput whole slide confocal imaging. Multiple types of projects - whether they are to be scanned in widefield fluorescence, or confocal fluorescence - can be easily color coded in the slide manager and scanned automatically with customizable scanning templates.

PROPERTIES

Design

Upright (Q+) or inverted (iQ+), Modular (Microscope, Cameras, Light-source, PC with 2 Monitors)

Microscopy mode

Confocal fluorescence, widefield fluorescence, (brightfield scanning - Q+ configuration)

Compatible Slide Formats

All standard and over-sized slides

Slide Capacity

8 (standard configuration) or 120 (slide loader configuration)

Objectives

Up to 7 Objectives (2.5-100x)

FL-Channels

6

Camera

Monochrome: sCMOS camera (16-bit, 2048x2048, monochrome)
Color: CMOS camera (Q+ configuration)

Light Source

Solid-state light engine

Tissue Microarray (TMA)

YES

Image Analysis Software

contextual image analysis - StrataQuest, StrataQuest Apps
single cell analysis - TissueQuest and HistoQuest

Supported Image Formats

TissueFAXS, OME-TIFF, TIFF, JPEG, BMP, PNG

Viewer

TissueFAXS Viewer: Integrated, stand-alone freeware

Contact

TissueGnostics GmbH
Taborstraße 10/2/8
1020 Vienna, Austria
+43 1 216 11 90
This email address is being protected from spambots. You need JavaScript enabled to view it.

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies).
You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.