Logo tissuegnostics
  • CONTEXTUAL IMAGE ANALYSIS

    Brightfield APPs


  • 1

Brightfield APPs

Brightfield APPs are designed to work on brightfield images and digital slides - usually these will be immunohistochemical stains, but for some requirements (e.g. fibrosis detection) histochemical stains can also be used and quantitatively evaluated. As opposed to immunofluorescence stainings, immunohistochemical stainings need to be color separated before being processed further for image analysis. In the following, find a representative selection of StrataQuest Brightfield APPs.

  • IF COEXPRESSION APP

    IHC²

    The IHC² APP unmixes two markers (e.g. chromogen and counterstain) in an IHC or HC digital slide and segments single cells into nucleus, and/or perinuclear area and/or cytoplasm. Each segmented cell compartment is measured for up to 20 intensity, statistic and morphometric parameters which are displayed in scattergrams and histograms and can be exported. 

    APP Category 1

     

  • IF COEXPRESSION APP

    IHC3

    The IHC3 APP unmixes three markers (e.g. two chromogens and counterstain) in an IHC or HC digital slide and segments single cells into nucleus, and/or perinuclear area and/or cytoplasm. Each segmented cell compartment is measured for up to 20 intensity, statistic and morphometric parameters which are displayed in scattergrams and histograms and can be exported.

    APP Category 2

  • IF COEXPRESSION APP

    IHC Membrane

    The IHC Membrane APP unmixes up to three markers in an IHC or HC digital slide and segments cells into nucleus, and/or perinuclear area and/or cytoplasm, as well as into membrane (e.g. HER2/neu). Each segmented cell compartment is measured for up to 20 intensity, statistic and morphometric parameters. Three more parameters are measured for membrane intensity and angle of staining. All parameters are displayed in scattergrams and histograms and can be exported.

    APP Category 2

  • IF COEXPRESSION APP

    IHC Angio

    The IHC Angio APP detects blood vessels based on appropriate stains (e.g. CD31) and measures overall vessel area as well as lumen area. The vessel detection also can be set to close open stained vessel walls and to connect separated vessel sections within a definable distance. The APP outputs number and vessel density as well as areas of vessels, endothelium and lumina.

    APP Category 2

  • IF COEXPRESSION APP

    RNA Scope

    The RNA Scope APP provides dot detection per cell within the nuclear compartment (nucleus and/or cytoplasm) for up to three markers in CISH and SISH experiments. Each segmented cell compartment is measured for up to 20 intensity, statistic and morphometric parameters. Dot parameters are provided per cell and include count, mean intensity, total dot area, and sum of intensity as well as area and intensity lists for all single dots.

    APP Category 2

  • IF COEXPRESSION APP

    CLASSIFIER

    The Classifier APP is based on trainable Deep Learning technology and provides tissue metastructure detection. In the above example it separates the colon tissue into crypts, stroma and infiltration areas. Combined with the IHC2 cellular detection APP the Ki-67+ nuclei in each compartment can be quantitatively analyzed for up to 20 parameters.

    APP Category 3

  • IF COEXPRESSION APP

    IHC ADIPOCYTE

    The IHC Adipocyte APP quantifies adipocytes as to their lumen in adequate HE samples. Small rips in adipocyte membranes are mended automatically and cell membrane artefacts in adipocyte lumina are automatically eliminated as are lumina on sample borders. The APP outputs area measurements for all detected adipocyte lumina.

    APP Category 1

  • IF COEXPRESSION APP

    IHC MACROPHAGES

    The IHC Macrophages APP detects macrophages based on adequately stained IHC samples. The APP can be combined with area detection and distance range algorithms, in the sample above to determine the distance of Langerhans cells from the border of the epidermis within and without. Each segmented cell compartment is measured for up to 20 parameters, as is the distance of each cell to the boundary.

    APP Category 3

  • IF COEXPRESSION APP

    IHC MULTI-SHADES

    The IHC Multi-Shades APP provides semi-automatic color separation for up to six markers or colors in an IHC or HC digital slide. In the above sample it has been used to detect and segment different levels of ossification based on Azan stain. Each detected area is measured for up to 20 intensity, statistic and morphometric parameters.

    APP Category 1

     

  • IF COEXPRESSION APP

    IHC META.CELLS

    The IHC Meta.Cells APP combines the detection of IHC/HC stained metastructures (e.g. Langerhans islets) with single cell detection (segmentation of cells into nucleus, and/or perinuclear area and/or cytoplasm). Detected cells can be classified and visualized as being either within or outside of detected metastructures. Each detected area and cell compartment is measured for up to 20 intensity, statistic and morphometric parameters.

    APP Category 2

     

  • IF COEXPRESSION APP

    IHC IMMUNE STATUS IN SITU

    The IHC Immune Status in Situ APP provides phenotypic characterization of immune cells in context with detected metastructures (e.g. tumors, glands). It measures the distance of cellular objects to the metastructure boundary (within and/or outside). Distance ranges can be defined. Each segmented cell compartment is measured for up to 20 parameters, as is the distance of each cell to the boundary.

    APP Category 3

  • IF COEXPRESSION APP

    PULMO

    The Pulmo APP segments the metastructure components of lung, including tissue, bronchioles, blood vessels and alveoles. Each segmented metastructure is measured for up to 20 morphometric parameters.

    APP Category 3

  • IF COEXPRESSION APP

    IHC TUMOR-STROMA

    The IHC Tumor-Stroma APP combines the segmentation of tumor and stroma (based on the morphology) and the detection of specifically stained cell populations. It segments the cells into nucleus, and/or perinuclear area and/or cytoplasm. Each segmented cell compartment in tumor and/or stroma is measured for up to 20 intensity, statistic and morphometric parameters which can be displayed in scattergrams and histograms and exported.

    APP Category 2

  • IF COEXPRESSION APP

    TUMOR FOCI

    The Tumor Foci APP allows to detect the whole tissue and more important tumor foci based on nuclear structure analysis, mainly on HE staining. The number and area of tumor foci as well as their density is measured. 

    APP Category 1

  • 1

Please follow the links to explore our StrataQuest AI solutions and Fluorescence APPs.

 

Contact

TissueGnostics GmbH
Taborstraße 10/2/8
1020 Vienna, Austria
+43 1 216 11 90
This email address is being protected from spambots. You need JavaScript enabled to view it.

We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience (tracking cookies).
You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site.